2000 kva transformer
I have found results from100000+products and30000+suppliers about2000 kva transformer
Bok 2000 kVA S20 Three Phase Oil Immersed Distribution Transformer
2000 kVA Three Phase Oil Cooled Transformer for Railway Electrification Project
S11 500kVA 2000 kVA Distribution Three Phase Electric Power Transformer 10kv 13.8kv 15kv 2000kVA Oil Immersed Prices
S11-M 500kVA 2000 kVA Distribution Three Phase Electric Power High Voltage Oil Immersed Transformer
2000 kVA and 2500 kVA 2.5 Mva Pad Mounted Transformer Price for Commercial Center
30 - 2500 kVA Power Supply Resin Cast Transformer with ISO9001-2000
2000 kVA Oil Filled Power Transformer Three Phase 10 Kv to 400V Hermetically Sealed S22 Distribution Transformer 50Hz
High Voltage Transformer 2000 kVA Commercial Building Electrical Oil Immersed Transformer
Affordable Factory Price 1250 kVA 2000 kVA 19.9/34.5kv 120/240V Oil Immersed Power Transformer
2000 kVA 20 Kv 10 Kv to 0.4 Tianhong Power Dry Type Distribution Transformer
Astor Transformer 250kVA S11/13/20/22 100/160/800/1000/ 1250/2000/1500/2500 kVA 10kv/0.4 250kVA Oil-Immersed Transformer
200kVA 500kVA 2000 kVA Three Phase Cast Resin Dry Type Power Transformer
2000 kVA Mobile Transformer: Efficient Emergency Power Solutions
2000 kVA Conservator-Tank Industrial Oil Transformer for Distribution Substation
10kv 25kv 415V 50 100kVA 160 400 kVA 500 630 1250kVA 1500 kVA 2000 kVA 2500kVA Power Transformer
1000 1250 1600 2000 2500 3000 kVA 10 / 0.4 Kv Phase 3 Stepdown Cast Resin Dry Type Power Distribution Transformer
2000 kVA 33kv Three-Phase Cast Resin Dry Transformer
3 Phases Electrical Transformer 1000kVA 1600 kVA 2000 kVA Oil Power Transformer
2000 kVA 3 Phase Dry Type Transformer Factory Direct Price
1500 kVA 1.5 Mva 2000 kVA 2500 kVA 3750 kVA Power Distribution Transformer for Heavy Duty Application
1000 ~ 2000 kVA Amorphous Alloy Core Dry Type Distribution Power Transformer
Sourcing guidance for 2000 Kva Transformer
What are the key technical specifications to evaluate when sourcing a 2000 KVA transformer?
Buyers must prioritize cooling methods (ONAN/ONAF), winding materials (Copper vs. Aluminum), and insulation classes. For a 2000 KVA unit, ensure the impedance voltage aligns with your system's short-circuit requirements. Additionally, verify the no-load and load loss levels, as high-efficiency models (e.g., meeting Tier 2 or EcoDesign standards) significantly reduce long-term operational costs.
Which international compliance standards are mandatory for high-capacity transformers?
The product must adhere to IEC 60076 (International Electrotechnical Commission) for power transformers. For specific markets, look for IEEE/ANSI C57 (North America) or CE/EN standards (Europe). Ensure the supplier provides Type Test Reports from accredited laboratories like KEMA or CESI to validate lightning impulse and temperature rise performance.
How do I choose between oil-immersed and dry-type 2000 KVA transformers?
Oil-immersed transformers are generally more cost-effective and durable for outdoor installations or heavy industrial use. However, for indoor environments, high-rise buildings, or fire-sensitive areas, Cast Resin Dry-Type transformers are preferred due to their self-extinguishing properties and minimal maintenance needs, despite a higher initial capital expenditure.
What customization options should a professional B2B supplier offer?
A qualified manufacturer should provide On-Load Tap Changers (OLTC) for voltage regulation, custom vector groups (e.g., Dyn11 or Ynd11), and specialized enclosures (IP ratings) based on the installation site. For renewable energy projects, request harmonics-resistant designs specifically for solar or wind grid integration.
Cross-Border Procurement & Risk Management for Heavy Electrical Equipment
How can I mitigate the risk of receiving a damaged or sub-standard transformer?
Always mandate a Factory Acceptance Test (FAT) before shipment. If you cannot visit the site, hire a third-party inspection agency (like SGS or Intertek) to witness the routine tests. Ensure the transformer is shipped with impact recorders to detect any excessive G-forces during transit that could shift the core or damage the windings.
What are the best practices for negotiating with transformer suppliers on Made-in-China.com?
Focus on the Total Cost of Ownership (TCO) rather than just the purchase price. Negotiate for an extended warranty (24-36 months) and request a detailed breakdown of the bill of materials (BOM), specifically the grade of silicon steel used. Suppliers on Made-in-China.com with Audited Supplier status are generally more reliable for high-value industrial assets.
What logistics and shipping precautions are necessary for a 2000 KVA unit?
Due to the weight (often exceeding 4,000kg), use FR (Flat Rack) containers or Heavy Lift vessels. Ensure the transformer is shipped without oil (if required by weight limits) and filled with dry nitrogen to prevent moisture ingress. Confirm that the supplier uses seaworthy packaging with vacuum-sealed moisture barriers for the control cabinet.
How do I ensure transaction security for high-value B2B electrical orders?
Utilize Letter of Credit (L/C) for large sums or the secured payment services provided by Made-in-China.com. Avoid full upfront payments; a standard structure is 30% deposit and 70% against the Bill of Lading (B/L) after successful third-party inspection reports are verified.





























