To ensure compatibility, request the EEPROM software architecture details to see if it supports various compressor brands (e.g., Highly, GMCC, Panasonic). Ask for Functional Circuit Test (FCT) and In-Circuit Test (ICT) reports from the manufacturer. It is critical to validate the protection logic, such as over-voltage, over-current, and phase-loss protection. For bulk orders, always request a Golden Sample to conduct a 'matching test' with your specific AC model's DC fan motor and electronic expansion valve (EEV).