SourcingAI

Tns

I have found results from5000+products and2000+suppliers aboutTns

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Current Type: AC
Phase: Three Phase
Usage: SVC
Size: Medium
Anti-skid design: Anti-slip Pattern
Close Pattern: Lace-up
Color: Black
Feature: Anti-microbial
Gender: Unisex
Insole Material: EVA
Lining Material: Genuine Leather
Material: Leather
Outsole Material: Rubber
Shock absorption: EVA Foam
Upper Material: Genuine Leather
Waterproof: Waterproof
Season: Autumn
Shoes Heel Height: High Heel
Frequency Characteristics: Low Frequency
Frequency: Low Frequency
Iron Core Shape: Ring
Linear Regulated Power Supply
Application Range: School
Usage: JIW
Size: Small
Size: Large
Anti-skid design: Anti-slip Grooves
Anti-skid design: Anti-slip Blades
Close Pattern: Ankle Zipper
Color: Beige
Color: White
Color: Yellow
Color: Multi
Color: Blue
Feature: Breathable
Feature: Resilient
Feature: Waterproof
Gender: Male
Insole Material: Rubber
Insole Material: PVC
Insole Material: TPR
Insole Material: PU
Lining Material: Cotton Fabric
Lining Material: Mesh
Material: Canvas
Material: Rubber
Material: Plush
Material: Fabric
Material: Cotton
Outsole Material: EVA
Outsole Material: PU
Outsole Material: TPR
Outsole Material: PVC
Shock absorption: Air Cushion
Upper Material: Flyknit
Upper Material: Mesh
Upper Material: Canvas
Upper Material: PU
Waterproof: Not Waterproof
Season: Summer
Season: Spring
Shoes Heel Height: Mid Heel
Shoes Heel Height: Flat
Frequency Characteristics: Power Frequency
Frequency: Industrial Frequency
Frequency: High Frequency
Switching Regulated Power Supply
Application Range: Hotel
Industrial and Mining Enterprises
Application Range: Construction Site

Sourcing guidance for Tns

How to choose a high-quality TNS device for professional or retail distribution?

Selecting a TNS (TENS) device requires a focus on medical-grade safety and pulse precision. Buyers should prioritize units with dual or quad-channel outputs, allowing users to treat multiple body areas simultaneously. Ensure the device offers a wide frequency range (typically 2Hz to 150Hz) and adjustable pulse width (50μs to 300μs) to cater to different pain management needs. For retail success, look for rechargeable lithium-ion batteries and backlit LCD screens which are currently high-demand features.

What are the essential compliance standards and certifications for TNS devices?

As medical devices, TNS units must adhere to strict international regulations. For the US market, FDA 510(k) clearance is mandatory. For the European market, CE Marking (MDR 2017/745) is required. Additionally, ensure the manufacturer is ISO 13485 certified, which guarantees a quality management system specifically for medical devices. RoHS and REACH compliance are also necessary to ensure the electrode pads and plastic casings are free from hazardous substances.

What technical specifications ensure the longevity of TNS electrode pads?

The quality of the hydrogel is the most critical factor for electrode pads. High-quality pads should be rated for 20 to 30 uses before losing adhesion. Specify biocompatible, non-sensitizing gels to prevent skin irritation. Furthermore, ensure the connection type—either 2mm pin or snap-on connectors—is standardized to ensure users can easily find replacement consumables, which creates a recurring revenue stream for distributors.

How can buyers evaluate the performance and safety of TNS units?

Request a Safety Test Report (IEC 60601-1) which covers the basic safety and essential performance of medical electrical equipment. Verify if the device includes an automatic power-off function when electrodes are detached and over-current protection. For performance validation, ask the supplier for oscilloscope wave-form images to ensure the pulse output is stable and matches the advertised specifications.

Cross-Border Procurement Considerations for TNS Devices

What are the primary risks when importing TNS devices from overseas?

The biggest risk is Customs seizure due to lack of medical registration. Ensure all documentation, including Declarations of Conformity and FDA listings, are verified before the goods leave the port. Another risk is battery-related shipping delays; since TNS devices contain lithium batteries, they must be shipped under UN38.3 regulations with proper MSDS documentation to avoid being rejected by airlines or shipping lines.

How should I negotiate with TNS suppliers on Made-in-China.com?

Focus on OEM/ODM capabilities and sample lead times. Ask for a tiered pricing structure based on volume, but insist on a pre-shipment inspection (PSI) by a third party like SGS or Intertek. Negotiate for a 1-2% spare parts allowance (especially for lead wires and pads) to handle initial customer returns without needing international shipping for small replacements.

What are the best practices for shipping medical electronics to ensure transaction security?

Use Secure Payment terms offered by platforms like Made-in-China.com to protect your funds until the shipping documents are uploaded. For shipping, choose DDP (Delivered Duty Paid) if you are unfamiliar with medical device import taxes, as the forwarder will handle the complex medical clearance process. Ensure the packaging includes moisture-proof barriers and anti-static shielding to protect the sensitive internal circuitry during long-haul sea freight.

Related queries