Erbium laser
I have found results from4000+products and1000+suppliers aboutErbium laser
Medical Grade 1550nm Erbium Glass 1927nm Thulium Non Ablative Fractional Laser Beauty Machine for Scar Removal
Best 4D Erbium Laser Machine Skin Resurfacing Medical Beauty Equipment Acne Scars Removal Vaginal Tightening Machine
Erbium Skin Tightening Snoring ND YAG Laser Hair Removal Reduction Beauty Machine
1550nm Erbium Laser Skin Rejuvenation Wrinkles Removal Machine
Er YAG 2940nm Erbium Laser and 1064nm ND YAG Lasers Hair Removal Laser Multifunctional Clinic Salon Beauty Equipments
2940nm Erbium YAG Laser 1064nm ND YAG Laser Skin Tightening Fat Reduction Hair Removal Skin Beauty Machine
Non-Ablative Erbium 1550nm Fractional Laser Skin Wrinkles Removal Face Lifting Machine
Premium Erbium YAG Laser System for Flawless Skin Treatment
Newest Erbium Glass 1550nm Fractional Laser Skin Rejuvenation Medical Aesthetics Machine
FDA Approved Erbium YAG Laser Machine Fractional CO2 Laser for Streckmarks Removal
Fractional CO2 Laser Skin Resurfacing Equipment Erbium 4D Fractional Laser Acne Scars Removal Machine
Professional Effective Scar Repair Aesthetic Device 1550 Fiber Laser Device Erbium Fiber Laser Machine with Various Scan Shape
Erbium Laser Medical Multi-Function Beauty Care Equipment Professional Laser 1550nm Fiber Laser for Scar Treatment Toning Fine Lines
Fotona 4D PRO Dynamis 2940nm Erbium Laser 1064nm Long Pulse Laser Face Lifting Wrinkle Removal Hair Removal CO2 Fractional Laser
Fotona 4D Erbium Laser Machine Skin Resurfacing Acne Scars Removal Vaginal Tightening Best Fractional CO2 Laser
Fotona 4D PRO Erbium Laser ND YAG Laser Skin Resurfacing Hair Removal
Winkonlaser Fractional CO2 Fractional Laser CO2 Laser Vaginal Tightening Machine CO2 Fractional Erbium Laser
Erbium YAG Laser 2940 for Hard Tissue Dentistry - Model Er-Tip
Fractional CO2 Laser Machine Fotona Erbium Portable RF Tube for Vaginal Rejuvenation
Sourcing guidance for Erbium Laser
What are the key technical specifications to consider when sourcing an Erbium Laser for medical or aesthetic use?
When evaluating Erbium lasers (typically Er:YAG at 2940nm or Er:Glass at 1540/1550nm), you must prioritize wavelength precision and pulse energy stability. For skin resurfacing, ensure the device offers fractional technology to minimize downtime. Key metrics include pulse duration (ranging from microseconds to milliseconds), spot size adjustability (1mm to 7mm), and repetition rate (Hz). High-quality units should feature a calibrated cooling system (air or water) to protect the laser crystal and ensure a lifespan of at least 500,000 to 1,000,000 shots.
Which international compliance standards are mandatory for Erbium Laser systems?
As a medical-grade device, the laser must adhere to ISO 13485 quality management systems for medical devices. For market entry, verify CE Marking (Medical Device Directive/Regulation) for Europe, FDA 510(k) clearance for the United States, and IEC 60601-1 for electrical safety. Additionally, ensure the product meets IEC 60825-1 standards for laser safety classification, which dictates necessary safety features like emergency stop buttons and key-lock switches.
How does the choice between Er:YAG and Er:Glass affect the procurement strategy?
The procurement choice depends on the intended application. Er:YAG (2940nm) is highly absorbed by water, making it the 'gold standard' for ablative resurfacing with high precision and minimal thermal damage. Er:Glass (1550nm) is non-ablative, penetrating deeper into the dermis without breaking the skin surface. Buyers should select suppliers based on their specialization in crystal growth and optical coating, as these components directly impact the beam quality (M² factor) and clinical efficacy.
What maintenance and after-sales support should a B2B buyer expect?
Erbium lasers require strict maintenance protocols. A professional supplier must provide a comprehensive technical manual and remote diagnostic support. Ensure the contract includes a warranty of at least 12-24 months covering the laser power supply and the laser head. Ask if the supplier provides plug-and-play replacement modules or has authorized service centers in your region to minimize operational downtime.
Cross-Border Procurement Risks and Strategies for Erbium Lasers
How can buyers mitigate the risk of receiving sub-standard optical components?
Request a factory inspection report or a third-party pre-shipment inspection (PSI) specifically focusing on the energy output consistency. Use platforms like Made-in-China.com to identify Audited Suppliers who have undergone independent verification of their manufacturing capabilities. Always request a video demonstration of the laser's energy meter reading before the final balance payment is made.
What are the essential logistics and packaging requirements for high-precision lasers?
Erbium lasers contain sensitive optical crystals and mirrors that are prone to misalignment from vibration. The product must be shipped in reinforced flight cases with shock-absorbent foam padding. Ensure the outer packaging includes 'Fragile' and 'This Side Up' labels, and consider using TiltWatch or ShockWatch sensors to monitor handling during transit. For international shipping, Air Freight is highly recommended over sea freight to reduce the duration of exposure to humidity and mechanical stress.
What negotiation strategies are effective when dealing with medical laser manufacturers?
Focus negotiations on long-term value rather than just the initial unit price. Negotiate for inclusive spare parts kits (such as extra protective windows or lenses) and free software updates. If purchasing in bulk, request OEM/ODM customization for the user interface (UI) and exterior casing to align with your brand. Discuss payment terms that involve an escrow service or a Letter of Credit (L/C) to ensure funds are only released upon verification of shipping documents.
How should buyers handle customs clearance for medical laser equipment?
Ensure the HS Code (typically 9018.90 or 9013.20) is correctly identified to determine applicable tariffs. The buyer must possess the necessary import licenses for medical devices required by their local health authority (e.g., ANVISA in Brazil, COFEPRIS in Mexico). Provide the customs broker with a detailed Commercial Invoice, Packing List, and the specific Certificate of Origin to benefit from any applicable Free Trade Agreements (FTAs).





























