SourcingAI

Electrical steel wire

I have found results from200000+products and80000+suppliers aboutElectrical steel wire

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Bare
Type: Insulated
Conductor Type: Stranded
Application: Overhead
Copper Clad Steel
Insulation Material: Bare
Material Shape: Round Wire
Range of Application: Refractory
Certification: ISO9001
Allowed Lateral Pressure: >1000(N/100mm)
Allowed Tensile Strength: >10000N
Brand: OEM
Sheath Material: PVC
Low and Medium Voltage Cable
DC & AC
Red Copper Wire
Surface Treatment: Oxidized
Alloy: Non-alloy
Material: Stainless Steel
Not Containing Flux
Extended Length: <10mm
Surface: Smooth
Technique: Drawn Wire
Alloy or Not: Non-alloy
Standard: BS
Cross Sectional Shape: Round
Metal Wire Drawing: Cold Drawing
Usage: Earthing System
Working Voltage: Low Voltage
Direct Earthing Method
Symbol: IT
Size: Meidum
Status: Soft State
Thickness: Metal Microfilament
Insulating Material: Bare
Conductor Type: Solid
Application: Communication
Application: Underground
Application: Heating
Application: Construction
Application: Industrial
Application: Power Station
Application: Telecommunication
Application: Computer
Application: Car
Application: Rope
Application: Packaging
Application: Netting
Application: Manufacturing
Application: Fencing
Application: Protecting Mesh
Application: Fence Mesh
Application: Filter
Application: High-rise Buildings
Construction Wire Mesh
Application: Decorative Mesh
Application: Screen
Application: Gabion Mesh
Application: Window Curtain
Barbecue Wire Mesh
Conductor Material: Copper
Conductor Material: Aluminum
Insulation Material: XLPE
Insulation Material: PVC
Insulation Material: Silicone Rubber
Range of Application: LSOH
Range of Application: Flame Retardant
Certification: CE
Certification: CCC
Certification: RoHS
Certification: VDE
Certification: ISO
Certification: ASTM
Certification: JIS
Certification: GB
Certification: EN
Certification: ASTMB
Certification: UL
Sheath Material: Crosslinking
Current: AC Cable
Current: DC Cable
Wire Core Material: Steel
Bare Copper Wire
Stainless Steel Wire
Material: Carbon Steel
Technique: Galvanized
Alloy or Not: Alloy
Standard: JIS
Standard: GB
Standard: ASTM
Standard: DIN
Standard: AISI

Sourcing guidance for Electrical Steel Wire

What are the key technical specifications to consider when sourcing electrical steel wire?

Buyers must prioritize conductivity and resistivity levels to ensure efficient power transmission. Key specifications include the tensile strength (measured in MPa) to withstand mechanical stress, wire gauge (AWG or mm) for circuit compatibility, and the type of coating (such as zinc for galvanized steel or aluminum cladding) to prevent corrosion. For high-voltage applications, verify the core strand configuration (e.g., 7-strand or 19-strand) to ensure structural flexibility and load-bearing capacity.

Which international compliance standards are mandatory for electrical steel wire?

To ensure safety and market entry, products should adhere to ASTM A363 (for concentric-lay-stranded steel guy wire) or ASTM A475 (for zinc-coated steel wire strand). For European markets, compliance with EN 50189 is essential. Additionally, ensure the manufacturer holds an ISO 9001:2015 certification for quality management and provides Mill Test Certificates (MTC) according to EN 10204 3.1 to trace the chemical composition and mechanical properties.

How does the environment affect the choice of electrical steel wire coating?

The choice of coating is critical for longevity and maintenance cycles. In coastal or high-humidity areas, Class C heavy zinc coating or Aluminum-clad (AS wire) is recommended for superior corrosion resistance. For standard inland environments, Class A or B galvanization may be sufficient and more cost-effective. Failure to match the coating to the environmental salinity can lead to premature oxidation and structural failure of the electrical grid.

What are the common usage scenarios for different grades of electrical steel wire?

Electrical steel wire is primarily used as overhead ground wire (shield wire) to protect transmission lines from lightning strikes, and as messenger wire for supporting telecommunication cables. High-tensile variants are used for guy wires to stabilize utility poles. In industrial settings, it serves as earthing (grounding) wire to ensure operational safety and prevent electrical surges from damaging equipment.

Cross-Border Procurement & Risk Management for Electrical Steel Wire

How can I mitigate quality risks when purchasing electrical steel wire from overseas?

Always request a pre-shipment inspection (PSI) conducted by a reputable third party like SGS or Intertek. Focus on zinc coating thickness tests (magnetic method) and tensile breaking strength tests. Ensure the contract specifies that the chemical composition (Carbon, Manganese, Silicon) must align with the agreed-upon grade to avoid brittle wire that could snap under tension.

What are the best strategies for negotiating with steel wire suppliers on Made-in-China.com?

Leverage volume-based pricing by requesting a tiered quote (e.g., 5 tons vs. 20 tons). Since steel is a commodity, negotiate based on the current London Metal Exchange (LME) or local steel index prices. Ask for flexible payment terms, such as a 30% deposit and 70% against the Bill of Lading (B/L), and prioritize Audited Suppliers on Made-in-China.com to ensure factory legitimacy.

What logistics and packaging precautions should be taken for international shipping?

Steel wire is heavy and prone to surface rust during sea transit. Insist on seaworthy packaging, which includes anti-rust paper (VCI), plastic film wrapping, and sturdy wooden or steel pallets. Ensure the container is moisture-protected with desiccant bags. Clearly define the Incoterms (e.g., FOB or CIF) to establish who bears the risk during the maritime leg of the journey.

How do international trade policies and tariffs impact the cost of electrical steel wire?

Be aware of Anti-Dumping Duties (ADD) and Countervailing Duties (CVD) that some countries impose on steel products from specific regions. Check your local Harmonized System (HS) Code (typically under 7217 or 7312) to calculate accurate import duties. Staying informed on Section 232 (US) or similar trade barriers is vital for accurate Total Cost of Ownership (TCO) calculations.

Related queries