SourcingAI

Rcd circuit breaker manufacturers

I have found results from400+products and200+suppliers aboutRcd circuit breaker

Wenzhou Santuo Electrical Co., Ltd.mic-icon
Satisfies 1/1 of your requirement
16A to 125A Residual Current Circuit Breaker RCCB a/AC Type RCD

16A to 125A Residual Current Circuit Breaker RCCB a/AC Type RCD

US$3.95-4.25
500 Pieces(MOQ)
Sample Available
Sontuoec New Model St16L 4p 63A/30mA RCCB Circuit Breaker RCD

Sontuoec New Model St16L 4p 63A/30mA RCCB Circuit Breaker RCD

US$6.75-6.95
500 Pieces(MOQ)
Sample Available
China Hot Selling 6ka RCD ELCB RCCB Circuit Breaker

China Hot Selling 6ka RCD ELCB RCCB Circuit Breaker

US$2.15-2.35
1,000 Pieces(MOQ)
Sample Available
One Series MCB+RCD Manufacturer Professional in Circuit Breakers

One Series MCB+RCD Manufacturer Professional in Circuit Breakers

US$0.53-0.54
20,000 Pieces(MOQ)
Sample Available
Recharge Station Protection Switch B Type RCCB Residual Current Circuit Breaker RCD

Recharge Station Protection Switch B Type RCCB Residual Current Circuit Breaker RCD

US$52.25
1,000 Pieces(MOQ)
Sample Available
2p 10ka Type a RCCB RCD ELCB Electromagnetic Residual Current Circuit Breaker

2p 10ka Type a RCCB RCD ELCB Electromagnetic Residual Current Circuit Breaker

US$6.62-6.75
1,000 Pieces(MOQ)
Sample Available
F360 Series 2p 4p RCD IEC61008 Residual Current Circuit Breaker RCCB

F360 Series 2p 4p RCD IEC61008 Residual Current Circuit Breaker RCCB

US$2.05-2.15
3,000 Pieces(MOQ)
Sample Available
2p 4p Professional 100AMP 6ka RCCB/RCD Circuit Breaker

2p 4p Professional 100AMP 6ka RCCB/RCD Circuit Breaker

US$1.95-2.05
2,000 Pieces(MOQ)
Sample Available
RCCB 4p 63A 30mA RCD Circuit Breaker Definition of a Circuit Breaker

RCCB 4p 63A 30mA RCD Circuit Breaker Definition of a Circuit Breaker

US$6.85-6.95
3,000 Pieces(MOQ)
Sample Available
Residual Current Circuit Breaker with Leakage Current Protection RCD

Residual Current Circuit Breaker with Leakage Current Protection RCD

US$1.95-2.05
2,000 Pieces(MOQ)
Sample Available
Sontuoec Stid-63 Series RCCB 2p 230V Residual Current Circuit Breaker RCD

Sontuoec Stid-63 Series RCCB 2p 230V Residual Current Circuit Breaker RCD

US$3.75
3,000 Pieces(MOQ)
Sample Available
ID Series RCD RCCB 6ka Residual Current Circuit Breaker Competitive Price

ID Series RCD RCCB 6ka Residual Current Circuit Breaker Competitive Price

US$1.95-2.05
1,000 Pieces(MOQ)
Sample Available
Residual Current Circuit Breaker EV Charger Leakage Protection RCD with CE ISO9001

Residual Current Circuit Breaker EV Charger Leakage Protection RCD with CE ISO9001

US$53.25
500 Pieces(MOQ)
Sample Available
RCCB 4p DIN Rail Residual Current Circuit Breaker RCD a Type

RCCB 4p DIN Rail Residual Current Circuit Breaker RCD a Type

US$2.35-2.45
1,000 Pieces(MOQ)
Sample Available
AC 63A 10mA Leakage RCD RCCB Residual Current Device Circuit Breaker ELCB

AC 63A 10mA Leakage RCD RCCB Residual Current Device Circuit Breaker ELCB

US$1.95-2.05
1,000 Pieces(MOQ)
Sample Available
Hg Type Residual Current Circuit Breakers RCCB, RCD 63A/30mA

Hg Type Residual Current Circuit Breakers RCCB, RCD 63A/30mA

US$5.25-5.35
2,000 Pieces(MOQ)
Sample Available
4p 63A 30mA ELCB Residual Current Circuit Breaker Magnetic Type RCD

4p 63A 30mA ELCB Residual Current Circuit Breaker Magnetic Type RCD

US$3.20-3.25
1,000 Pieces(MOQ)
Sample Available
St360 Series Leakage Cent Circuit Breaker RCCB, IP20 RCD

St360 Series Leakage Cent Circuit Breaker RCCB, IP20 RCD

US$3.20-3.25
3,000 Pieces(MOQ)
Sample Available
Sontuoec Hg Type Residual Current Circuit Breakers RCCB, RCD 63A/30mA

Sontuoec Hg Type Residual Current Circuit Breakers RCCB, RCD 63A/30mA

US$5.25-5.35
2,000 Pieces(MOQ)
Sample Available
RCD Nfin 2p 4p SKD Spare Parts for Circuit Breaker RCCB

RCD Nfin 2p 4p SKD Spare Parts for Circuit Breaker RCCB

US$4.65-4.75
3,000 Pieces(MOQ)
Sample Available
RCD Snfin 4p SKD Spare Parts for Residual Current Circuit Breaker RCCB

RCD Snfin 4p SKD Spare Parts for Residual Current Circuit Breaker RCCB

US$4.65-4.75
3,000 Pieces(MOQ)
Sample Available
Residual Current Circuit Breakers RCCB, RCD 2 Pole 25A 4pole 100A

Residual Current Circuit Breakers RCCB, RCD 2 Pole 25A 4pole 100A

US$4.35-4.45
2,000 Pieces(MOQ)
Sample Available
100A Residual Current Circuit Breaker 35mm Cable Screw Terminal Connection RCD

100A Residual Current Circuit Breaker 35mm Cable Screw Terminal Connection RCD

US$1.91-1.95
2,000 Pieces(MOQ)
Sample Available
RCCB Residual Current Circuit Breaker AC220V 2p 40A 30mA RCD Professional Manufacturer

RCCB Residual Current Circuit Breaker AC220V 2p 40A 30mA RCD Professional Manufacturer

US$1.90-1.95
2,000 Pieces(MOQ)
Sample Available
RCBO MCB + RCD Pg230 Pg430 Adjustable Current Earth Leakage Circuit Breaker

RCBO MCB + RCD Pg230 Pg430 Adjustable Current Earth Leakage Circuit Breaker

US$7.25-7.65
100 Pieces(MOQ)
Sample Available
Plug in Type MCB+RCD 16A/30mA Residual Current Circuit Breaker

Plug in Type MCB+RCD 16A/30mA Residual Current Circuit Breaker

US$3.65-3.85
2,000 Pieces(MOQ)
Sample Available
Sontuoec MCB + RCD Pg230 Pg430 Adjustable Current Earth Leakage Circuit Breaker

Sontuoec MCB + RCD Pg230 Pg430 Adjustable Current Earth Leakage Circuit Breaker

US$7.25-7.65
100 Pieces(MOQ)
Sample Available
Sontuoec Plug in Type MCB+RCD 16A/30mA Residual Current Circuit Breaker

Sontuoec Plug in Type MCB+RCD 16A/30mA Residual Current Circuit Breaker

US$3.45-3.65
2,000 Pieces(MOQ)
Sample Available
Yueqing Long Road Electric Co., Ltd.mic-icon
Satisfies 1/1 of your requirement

Sourcing guidance for Rcd Circuit Breaker

What are the key technical specifications to consider when selecting an RCD (Residual Current Device)?

When sourcing RCDs, you must prioritize the Rated Current (In), typically ranging from 16A to 125A, and the Rated Residual Operating Current (IΔn), where 30mA is the standard for life safety and 100mA-500mA is used for fire protection. Additionally, verify the Breaking Capacity (Icn), ensuring it meets a minimum of 6kA or 10kA for industrial applications to handle short-circuit faults safely.

How do I choose between Type AC, Type A, and Type B RCDs for different markets?

The choice depends on the load type: Type AC is for standard sinusoidal AC currents but is being phased out in many EU markets. Type A is the most common for residential use as it handles pulsating DC components from electronics. For EV charging stations and solar PV installations, you must source Type B RCDs, which detect high-frequency AC and smooth DC leakage currents. Always check the IEC 61008-1 or IEC 61009-1 standards for global compliance.

What environmental factors affect the performance of RCD circuit breakers?

RCDs are sensitive to operating temperature and humidity. Ensure the units are rated for -25°C to +40°C for outdoor or industrial enclosures. For coastal or high-humidity regions, specify tropicalized versions with anti-corrosion treatments on internal components to prevent nuisance tripping or mechanical failure of the trip mechanism.

What are the requirements for product durability and lifespan?

A high-quality RCD should have a mechanical life of at least 10,000 operations and an electrical life of 4,000 operations. Look for suppliers on Made-in-China.com that provide silver alloy contacts to ensure low contact resistance and long-term reliability under heavy load switching.

Cross-Border Procurement Risks and Strategies for RCDs

How can I verify the authenticity of safety certifications for international trade?

Electrical components must carry CE, CB, TUV, or UL marks depending on the destination. Do not rely on photos; request the Certificate Number and verify it directly on the issuing body's database. Ensure the factory name on the test report matches the supplier to avoid 'trading company' risks where the product quality may vary from the tested sample.

What are the best practices for negotiating with RCD manufacturers?

Focus on the Copper vs. Aluminum content in internal components; lower prices often indicate substituted materials. Negotiate based on Total Cost of Ownership, requesting a 2-5 year warranty period. For bulk orders, insist on a 0.5% spare parts allowance to cover potential DOA (Dead on Arrival) units without needing individual returns.

How should RCDs be packaged and shipped to prevent damage?

Circuit breakers contain delicate calibration springs. Ensure the supplier uses individual inner boxes and double-walled corrugated master cartons with moisture-proof plastic lining. For sea freight, specify fumigated pallets and avoid stacking more than 5 layers high to prevent crushing the internal mechanisms of the bottom units.

What transaction security measures should be taken for large electrical orders?

Utilize Secured Trading services on Made-in-China.com to ensure payment is only released upon proof of shipment. For first-time large orders, hire a third-party inspection agency (like SGS or Intertek) to perform a Random Sampling Test focusing on the 'Trip Test' and 'Dielectric Strength' before the final balance is paid.

Related queries