Defrost heater for refrigerator
I have found results from6000+products and2000+suppliers aboutDefrost heater for refrigerator
Refrigerator Defrosting Hheater Defrost Heater for Refrigerator Glass Defrost Heater
High Dielectric Strength Defrost Refrigerator Heating Tube Tubular Heater
12V 24V 48V DC U Shape Stainless Steel Defrost Heater with Lead Wire for for Freezer Refrigerator
35W Aluminium Foil Heater Plate for Defrost Refrigerator Electric Heater Element
Premium Refrigerator Defrost Heater Sheath for OEM Models
Premium Defrost Heater for Refrigerators - Ap5583429 & PS4140703
Frigidaire Electrolux Refrigerator Evaporator Parts 242044020 242044008 Defrost Heater Kit
60128-0005503-00 Refrigerator Fridge Freezer Stainless Steel Tubes Defrost Heater for Evaporator
for Samsung Refrigerator Defrost Heater 280W Da47-00139A Heating Element Replacement
Wholesale Electric Heating Resistance Aluminum Foil Heater for Refrigerator Defrost
Electric Aluminum Tubular Defrost Heating Element/Heater for Refrigerator, Freezer
Frost-Free Refrigerator Defrost Heater with Aluminum Foil Heater
Glass Tuber Heater for Window Heaters or Refrigerator Defrost
Double Aluminum Foil Heater for Refrigerator Defrost Heater
Manufacture Refrigerator Defrost Heater with Evaporator Al Tube Heater
Aluminum Tube Heating Element for Refrigerator Electric Defrost Heater
Laiyuan China Supplier High Efficient Aluminum Foil Defrost Heater for Refrigerator
Laiyuan China Supplier 110V 220W Electric Resistance Defrost Heater Heating Element for Refrigerator
Stainless Steel Tubular Cold Storage Replacement Parts Refrigerator Defrost Heater Resistance
Custom Aluminum Foil Heating Sheet, Refrigerator Defrost Foil Heater for Fridge Drain Pan Anti-Icing
Custom Shape Aluminum Foil Heating Sheet, Refrigerator Freezer Defrost Aluminum Foil Heater Element
Sourcing guidance for Defrost Heater For Refrigerator
What are the key technical specifications to consider when selecting a defrost heater?
Buyers must prioritize tube material, typically Stainless Steel (304/316) or Incoloy, for corrosion resistance. The wattage and voltage must match the refrigerator's compressor system (e.g., 110V/220V). Additionally, ensure the insulation resistance is ≥100MΩ and the dielectric strength can withstand 1500V/min without breakdown to prevent electrical leakage in high-moisture environments.
How do I ensure the defrost heater is compatible with specific refrigerator models?
Compatibility is determined by the shape (U-shape, M-shape, or straight) and the overall length/diameter of the heating element. You should request technical drawings (CAD/PDF) from the supplier to verify the terminal type and lead wire length. For OEM/ODM orders, ensure the supplier can provide customized bending to fit the evaporator coils precisely.
What quality certifications are mandatory for international trade of heating elements?
To ensure safety and market entry, products should carry UL or CSA certification for North America, and CE or VDE certification for the European market. Compliance with RoHS and REACH is essential to guarantee the absence of hazardous substances. Always ask for ISO 9001:2015 factory audit reports to verify consistent manufacturing processes.
What performance tests should be requested from the supplier before bulk shipment?
Request a Life Cycle Test report to ensure the heater can withstand at least 5,000 to 10,000 defrost cycles. Other critical tests include the Waterproof Grade Test (IP65 or higher), Cold/Hot Leakage Current Test, and Salt Spray Test for components used in coastal regions or high-humidity environments.
Cross-Border Procurement & Risk Management for Defrost Heaters
What are the common risks when sourcing defrost heaters from overseas?
The primary risk is specification mismatch, where slight deviations in tube diameter or wattage lead to system failure. Another risk is oxidation during transit; ensure the supplier uses vacuum packaging or moisture-proof silica gel inside the shipping cartons. To mitigate transaction risks, use Secured Trading Services on Made-in-China.com to protect your payment until the goods pass inspection.
How can I negotiate better terms with defrost heater manufacturers?
Focus on Annual Purchase Volume (APV) rather than single-order quantity to secure tiered pricing. Negotiate for a 1-2% spare parts allowance (FOC - Free of Charge) to cover potential damages during installation. For long-term partnerships, request Net 30 or Net 60 payment terms after a successful trial period to improve your cash flow.
What are the logistics and shipping precautions for fragile heating tubes?
Defrost heaters, especially glass-tube variants, are highly fragile. Insist on honeycomb cardboard packaging or wooden crates for LCL shipments. Ensure the Incoterms are clearly defined; CIF or CIP is recommended for new buyers to ensure the supplier handles insurance. Always verify the HS Code (typically 8516.80) to calculate accurate import duties in your destination country.




























